MAYO2: W. D. Mayo Lock And Dam (L&D 14)

                                SHEF ID:       MAYO2     W.D. Mayo LD14
STATION TYPE: NAVIGATION LOCK
Navigation Pool: Bottom = 411.00, Top = 413.00

PRECIP ELEVATION STORAGE TW-ELEV LOCK-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in ft ac-ft ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
05/08 00:00 0.00 412.27 34638 393.94 ---- 34502 34665 54.16 216.40 0.10 89.90 0.00 13.57 13.25
05/08 01:00 0.00 412.26 34611 393.99 ---- 34553 34597 52.18 220.50 0.20 92.40 0.00 13.57 13.26
05/08 02:00 0.00 412.25 34584 393.95 ---- 33909 34588 53.98 40.30 0.90 90.87 0.00 13.57 13.26
05/08 03:00 0.00 412.25 34584 393.86 ---- 33446 34583 54.09 33.10 1.10 87.82 0.00 13.58 13.26
05/08 04:00 0.00 412.17 34380 394.04 ---- 33350 34550 53.11 28.30 1.10 90.09 0.00 13.58 13.26
05/08 05:00 0.00 412.10 34177 392.79 ---- 32919 34483 52.63 160.50 0.90 88.81 0.00 13.57 13.26
05/08 06:00 0.00 412.08 34123 392.48 ---- 32517 34441 51.30 83.00 0.90 92.26 0.00 13.57 13.27
05/08 07:00 0.00 412.01 33934 392.55 ---- 32903 34401 51.06 44.70 1.30 91.07 13.40 13.57 13.27
05/08 08:00 0.00 411.95 33788 392.49 ---- 33476 34342 52.66 37.10 1.30 87.66 140.60 13.56 13.28
05/08 09:00 0.00 411.94 33764 392.39 ---- 33525 34310 57.09 45.50 1.70 79.90 338.00 13.57 13.27
05/08 10:00 0.00 411.96 33811 392.36 ---- 34024 34314 62.53 118.00 1.10 70.19 522.20 13.57 13.27
05/08 11:00 0.00 411.95 33788 392.23 ---- 34140 34319 69.17 140.50 2.00 58.66 674.00 13.56 13.28
05/08 12:00 0.00 411.96 33811 392.20 ---- 34428 34319 71.58 274.60 2.90 53.83 779.00 13.58 13.27
05/08 13:00 0.00 411.92 33716 392.11 ---- 34314 34305 73.80 162.90 3.40 47.57 844.30 13.58 13.26
05/08 14:00 0.00 411.96 33811 392.05 ---- 34314 34305 75.51 143.30 3.90 45.28 855.70 13.58 13.27
05/08 15:00 0.00 411.96 33811 392.09 ---- 34256 34324 77.11 153.40 3.60 42.35 817.40 13.58 13.29
05/08 16:00 0.00 411.95 33788 392.07 ---- 34430 34319 78.49 162.70 3.80 42.62 729.70 13.58 13.26
05/08 17:00 0.00 411.95 33788 392.06 ---- 34201 34314 79.25 154.70 4.20 43.28 593.40 13.57 13.27
05/08 18:00 0.00 411.94 33764 392.06 ---- 34082 34310 79.88 155.30 3.70 43.58 426.80 13.57 13.26
05/08 19:00 0.00 411.99 33883 393.02 ---- ---- ---- 79.20 148.50 5.10 45.18 227.30 ---- ----
05/08 20:00 0.00 412.01 33934 393.16 ---- ---- ---- 76.86 168.50 1.80 50.50 8.30 13.57 13.29
05/08 21:00 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
05/08 22:00 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
05/08 23:00 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
Data processed at Sat 09May2026 01:31 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting early 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. When this migration completes you will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
WDMA.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
WDMA.Elev.Inst.1Hour.0.Ccp-Rev
WDMA.Stor.Inst.1Hour.0.Ccp-Rev
WDMA.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
WDMA.Elev-Lock Chamber.Inst.1Hour.0.Ccp-Rev
WDMA.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
WDMA.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
WDMA.Temp-Air.Inst.1Hour.0.Ccp-Rev
WDMA.Dir-Wind.Inst.1Hour.0.Ccp-Rev
WDMA.Speed-Wind.Inst.1Hour.0.Ccp-Rev
WDMA.%-Humidity.Inst.1Hour.0.Ccp-Rev
WDMA.Irrad.Inst.1Hour.0.Ccp-Rev
WDMA.Volt-Battery.Inst.1Hour.0.Ccp-Rev
WDMA.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.