MAYO2: W. D. Mayo Lock And Dam (L&D 14)

                                SHEF ID:       MAYO2     W.D. Mayo LD14
STATION TYPE: NAVIGATION LOCK
Navigation Pool: Bottom = 411.00, Top = 413.00

PRECIP ELEVATION STORAGE TW-ELEV LOCK-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in ft ac-ft ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
05/07 00:00 0.00 412.28 34665 394.59 ---- 39082 39152 52.00 259.70 0.00 86.74 0.00 13.57 13.30
05/07 01:00 0.00 412.31 34746 394.46 ---- 39141 39122 50.41 274.70 0.50 90.81 0.00 13.57 13.29
05/07 02:00 0.00 412.30 34719 394.57 ---- 39068 39132 49.10 245.60 0.50 93.10 0.00 13.57 13.30
05/07 03:00 0.00 412.31 34746 394.55 ---- 39326 39132 47.79 264.10 0.80 95.89 0.00 13.57 13.29
05/07 04:00 0.00 412.30 34719 394.59 ---- 39000 39132 46.92 265.40 0.40 95.58 0.00 13.57 13.30
05/07 05:00 0.00 412.31 34746 394.53 ---- 38663 39132 45.21 221.60 0.30 96.49 0.00 13.58 13.29
05/07 06:00 0.00 412.29 34692 394.51 ---- 39181 39127 44.60 235.00 0.50 96.76 0.00 13.57 13.29
05/07 07:00 0.00 412.23 34529 394.42 ---- 38984 39086 44.06 227.30 0.50 97.04 11.50 13.58 13.29
05/07 08:00 0.00 412.32 34773 394.61 ---- 39246 39101 47.70 207.30 0.50 93.13 135.00 13.58 13.29
05/07 09:00 0.00 412.28 34665 394.39 ---- 38283 39127 52.88 163.40 1.30 76.05 327.50 ---- ----
05/07 10:00 0.00 412.33 34800 394.39 ---- 37652 39132 56.17 136.60 3.30 64.26 510.10 13.57 13.29
05/07 11:00 0.00 412.30 34719 394.14 ---- 36230 34641 61.84 54.20 1.70 53.40 665.40 13.57 13.29
05/07 12:00 0.00 412.28 34665 394.06 ---- 35524 34619 64.71 11.10 2.10 49.09 760.50 13.57 13.29
05/07 13:00 0.00 412.29 34692 393.88 ---- 34292 34614 65.53 333.20 3.30 39.77 799.60 13.57 13.29
05/07 14:00 0.00 412.28 34665 393.95 ---- 34482 34614 68.02 326.20 2.80 37.32 859.00 13.57 13.28
05/07 15:00 0.00 412.28 34665 393.91 ---- 34545 34610 69.31 311.90 3.50 34.22 836.10 13.57 13.30
05/07 16:00 0.00 412.28 34665 393.92 ---- 34610 34610 70.07 329.00 4.70 34.39 752.20 13.57 13.26
05/07 17:00 0.00 412.27 34638 394.03 ---- 34610 34605 70.48 330.00 4.60 35.98 616.50 13.58 13.26
05/07 18:00 0.00 412.29 34692 393.84 ---- 34610 34610 71.38 335.30 3.80 35.24 446.30 13.56 13.27
05/07 19:00 0.00 412.28 34665 394.01 ---- 34543 34614 71.44 336.20 3.40 36.81 255.80 13.57 13.26
05/07 20:00 0.00 412.28 34665 393.88 ---- 34542 34610 70.45 280.80 0.50 40.38 72.20 13.57 13.24
05/07 21:00 0.00 412.27 34638 393.99 ---- 34344 34605 61.48 232.00 0.10 62.78 0.00 13.57 13.24
05/07 22:00 0.00 412.26 34611 393.99 ---- 34339 34597 57.81 239.70 0.10 75.06 0.00 13.55 13.24
05/07 23:00 0.00 412.28 34665 393.94 ---- ---- ---- 55.58 277.80 0.00 83.65 0.00 13.56 13.25
Data processed at Fri 08May2026 04:31 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting early 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. When this migration completes you will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
WDMA.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
WDMA.Elev.Inst.1Hour.0.Ccp-Rev
WDMA.Stor.Inst.1Hour.0.Ccp-Rev
WDMA.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
WDMA.Elev-Lock Chamber.Inst.1Hour.0.Ccp-Rev
WDMA.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
WDMA.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
WDMA.Temp-Air.Inst.1Hour.0.Ccp-Rev
WDMA.Dir-Wind.Inst.1Hour.0.Ccp-Rev
WDMA.Speed-Wind.Inst.1Hour.0.Ccp-Rev
WDMA.%-Humidity.Inst.1Hour.0.Ccp-Rev
WDMA.Irrad.Inst.1Hour.0.Ccp-Rev
WDMA.Volt-Battery.Inst.1Hour.0.Ccp-Rev
WDMA.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.