TENO2: Tenkiller Lake

                                SHEF ID:       TENO2     Tenkiller Lake
STATION TYPE: Reservoir
Flood Pool: Bottom = 632.00, Top = 667.00

PRECIP PRECIP(A) ELEVATION STORAGE TW-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in in ft ac-ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
09/09 00:00 0.00 ---- 626.93 605358 482.26 26 92 78.48 185.20 0.00 79.98 0.20 13.53 13.26
09/09 01:00 0.00 ---- 626.93 605358 482.25 17 92 77.32 183.00 0.00 83.09 0.20 13.53 13.25
09/09 02:00 0.00 ---- 626.92 605240 482.25 19 92 76.50 179.00 0.00 85.21 0.30 13.52 13.26
09/09 03:00 0.00 ---- 626.93 605358 482.24 20 92 75.51 181.90 0.00 86.46 0.30 13.53 13.26
09/09 04:00 0.00 ---- 626.92 605240 482.24 21 92 74.79 193.70 0.00 87.12 0.40 13.53 13.26
09/09 05:00 0.00 ---- 626.93 605358 482.24 17 92 74.37 192.90 0.00 87.63 0.20 13.53 13.37
09/09 06:00 0.00 ---- 626.93 605358 482.25 17 92 73.76 195.10 0.00 88.90 0.40 13.53 13.25
09/09 07:00 0.00 ---- 626.92 605240 482.25 15 92 73.36 183.00 0.00 90.02 0.20 13.53 13.26
09/09 08:00 0.00 ---- 626.92 605240 482.26 13 92 74.46 177.20 0.00 88.29 43.60 13.53 13.24
09/09 09:00 0.00 ---- 626.91 605122 482.25 10 92 81.95 186.30 1.00 72.67 255.70 13.53 13.25
09/09 10:00 0.00 ---- 626.92 605240 482.24 11 92 87.96 232.00 2.30 61.26 473.30 13.53 13.26
09/09 11:00 0.00 ---- 626.93 605358 482.24 16 92 91.00 237.10 2.30 55.97 679.50 13.53 13.26
09/09 12:00 0.00 ---- 626.92 605240 482.24 14 92 93.92 225.00 3.10 48.92 826.30 13.53 13.26
09/09 13:00 0.00 ---- 626.91 605122 482.56 13 92 96.12 212.50 2.70 44.20 885.70 13.53 13.26
09/09 14:00 0.00 ---- 626.90 605004 486.82 11 3848 97.74 218.30 2.50 40.49 895.60 13.53 13.25
09/09 15:00 0.00 ---- 626.87 604650 486.90 10 3848 99.43 268.20 2.60 35.73 843.00 13.53 13.24
09/09 16:00 0.00 ---- 626.84 604296 486.92 2 3848 100.54 220.40 2.50 32.26 811.40 13.53 13.24
09/09 17:00 0.00 ---- 626.81 603941 486.92 1 3848 101.35 237.30 2.50 31.25 604.40 13.53 13.24
09/09 18:00 0.00 ---- 626.78 603587 486.94 70 3848 100.81 242.60 1.70 30.94 347.70 13.53 13.24
09/09 19:00 0.00 ---- 626.75 603233 486.94 128 3848 97.65 231.00 1.00 34.99 29.50 13.53 13.24
09/09 20:00 0.00 ---- 626.73 602997 486.97 151 3945 90.32 187.00 0.10 49.00 1.70 13.53 13.25
09/09 21:00 0.00 ---- 626.71 602761 486.91 209 3751 84.52 185.30 0.00 60.59 0.30 13.53 13.26
09/09 22:00 0.00 ---- 626.71 602761 482.80 199 365 81.45 197.80 0.00 67.68 0.10 13.53 13.26
09/09 23:00 0.00 ---- 626.69 602525 482.32 ---- ---- 79.43 189.40 0.00 72.20 0.10 13.53 13.24
Data processed at Thu 10Sep2026 04:31 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting early 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. When this migration completes you will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
TENK.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
TENK.Precip-Inc Alt.Total.1Hour.1Hour.Ccp-Rev
TENK.Elev.Inst.1Hour.0.Ccp-Rev
TENK.Stor.Inst.1Hour.0.Ccp-Rev
TENK.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
TENK.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
TENK.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
TENK.Temp-Air.Inst.1Hour.0.Ccp-Rev
TENK.Dir-Wind.Inst.1Hour.0.Ccp-Rev
TENK.Speed-Wind.Inst.1Hour.0.Ccp-Rev
TENK.%-Humidity.Inst.1Hour.0.Ccp-Rev
TENK.Irrad.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.