TENO2: Tenkiller Lake

                                SHEF ID:       TENO2     Tenkiller Lake
STATION TYPE: Reservoir
Flood Pool: Bottom = 632.00, Top = 667.00

PRECIP PRECIP(A) ELEVATION STORAGE TW-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in in ft ac-ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
04/20 00:00 0.00 ---- 633.11 683368 481.95 2629 0 48.15 203.50 0.10 93.75 1.30 13.18 12.70
04/20 01:00 0.00 ---- 633.14 683763 481.86 2871 0 46.40 204.90 0.10 95.59 1.60 13.18 12.70
04/20 02:00 0.00 ---- 633.14 683763 481.82 2871 0 44.91 208.00 0.30 97.15 3.00 13.18 12.70
04/20 03:00 0.00 ---- 633.17 684159 481.81 2871 0 44.19 200.00 0.20 97.13 1.70 13.18 12.70
04/20 04:00 0.00 ---- 633.19 684422 481.81 2332 0 43.32 198.60 0.20 97.60 2.00 13.18 12.69
04/20 05:00 0.00 ---- 633.20 684554 481.80 2692 0 42.44 205.00 0.20 97.84 1.60 13.18 12.69
04/20 06:00 0.00 ---- 633.21 684686 482.35 2444 494 41.99 191.70 0.20 97.87 1.60 13.17 12.70
04/20 07:00 0.00 ---- 633.20 684554 486.71 1888 3396 42.42 173.90 0.30 97.12 3.90 13.18 12.70
04/20 08:00 0.00 ---- 633.20 684554 486.69 1952 3545 44.19 144.10 0.50 93.03 115.10 13.18 12.70
04/20 09:00 0.00 ---- 633.18 684291 486.76 1936 3600 52.14 123.30 0.30 78.25 377.60 13.18 12.70
04/20 10:00 0.00 ---- 633.17 684159 486.76 1977 3511 60.39 168.80 0.70 62.86 590.40 13.18 12.70
04/20 11:00 0.00 ---- 633.16 684027 486.72 1651 3600 65.35 213.80 1.80 48.26 811.30 13.18 12.70
04/20 12:00 0.00 ---- 633.15 683895 486.82 1970 3600 67.80 252.70 3.10 40.50 954.80 13.18 12.70
04/20 13:00 0.00 ---- 633.14 683763 486.84 2289 3511 69.22 207.10 4.00 34.00 998.10 13.18 12.70
04/20 14:00 0.00 ---- 633.13 683632 486.75 1970 3600 70.29 212.00 3.70 32.42 990.60 13.18 12.71
04/20 15:00 0.00 ---- 633.13 683632 486.77 2289 3511 71.74 222.30 3.00 31.29 980.80 13.17 12.70
04/20 16:00 0.00 ---- 633.11 683368 486.79 2307 3600 72.59 208.00 3.50 31.31 880.40 13.18 12.71
04/20 17:00 0.00 ---- 633.11 683368 486.80 2289 3600 73.22 224.00 2.90 32.62 633.80 13.18 12.70
04/20 18:00 0.00 ---- 633.10 683236 486.82 2289 3600 72.52 192.70 1.90 34.58 364.30 13.18 12.71
04/20 19:00 0.00 ---- 633.09 683104 486.78 2608 3511 70.45 250.90 1.50 37.83 97.20 13.18 12.70
04/20 20:00 0.00 ---- 633.09 683104 486.73 2271 3511 66.34 235.30 0.50 46.04 17.50 13.18 12.70
04/20 21:00 0.00 ---- 633.08 682972 486.82 2271 3600 58.64 164.90 0.00 71.19 0.50 13.18 12.70
04/20 22:00 0.00 ---- 633.07 682841 486.82 2253 3511 54.39 196.80 0.20 83.60 1.50 13.18 12.70
04/20 23:00 0.00 ---- 633.08 682972 482.59 ---- ---- 51.64 204.00 0.40 88.61 3.20 13.18 12.70
Data processed at Tue 21Apr2026 04:31 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting early 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. When this migration completes you will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
TENK.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
TENK.Precip-Inc Alt.Total.1Hour.1Hour.Ccp-Rev
TENK.Elev.Inst.1Hour.0.Ccp-Rev
TENK.Stor.Inst.1Hour.0.Ccp-Rev
TENK.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
TENK.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
TENK.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
TENK.Temp-Air.Inst.1Hour.0.Ccp-Rev
TENK.Dir-Wind.Inst.1Hour.0.Ccp-Rev
TENK.Speed-Wind.Inst.1Hour.0.Ccp-Rev
TENK.%-Humidity.Inst.1Hour.0.Ccp-Rev
TENK.Irrad.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.