TENO2: Tenkiller Lake

                                SHEF ID:       TENO2     Tenkiller Lake
STATION TYPE: Reservoir
Flood Pool: Bottom = 632.00, Top = 667.00

PRECIP PRECIP(A) ELEVATION STORAGE TW-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in in ft ac-ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
01/20 00:00 0.00 ---- 627.04 606663 482.68 387 346 22.30 131.10 1.20 75.06 2.30 13.17 12.76
01/20 01:00 0.00 ---- 627.02 606424 482.30 387 73 21.38 149.50 0.90 79.91 2.00 13.17 12.76
01/20 02:00 0.00 ---- 627.04 606663 482.25 52 73 20.26 150.60 1.00 84.61 2.30 13.17 12.77
01/20 03:00 0.00 ---- 627.02 606424 482.70 7 346 19.40 158.80 1.30 85.06 2.40 13.17 12.77
01/20 04:00 0.00 ---- 627.01 606304 486.70 17 3732 19.00 152.90 1.20 83.10 2.50 13.17 12.77
01/20 05:00 0.00 ---- 626.98 605948 486.75 37 3829 18.64 142.50 1.40 83.41 2.70 13.17 12.77
01/20 06:00 0.00 ---- 626.94 605476 486.80 37 3732 17.56 130.10 1.50 88.53 2.50 13.17 12.77
01/20 07:00 0.00 ---- 626.93 605358 486.82 37 3829 19.02 123.00 0.90 88.83 1.90 13.17 12.77
01/20 08:00 0.00 ---- 626.90 605004 486.89 37 3829 18.88 128.90 0.90 96.75 9.50 13.17 12.77
01/20 09:00 0.00 ---- 626.87 604650 486.90 128 3732 25.83 101.70 1.60 64.10 198.70 13.16 12.77
01/20 10:00 0.00 ---- 626.84 604296 486.82 138 3829 31.12 126.90 2.30 44.24 391.80 13.17 12.77
01/20 11:00 0.00 ---- 626.83 604177 486.83 142 3635 34.47 113.70 3.50 36.71 553.60 13.17 12.77
01/20 12:00 0.00 ---- 626.83 604177 482.68 142 619 38.30 141.50 4.00 30.72 646.80 13.17 12.77
01/20 13:00 0.00 ---- 626.80 603823 482.29 142 73 42.06 139.10 3.80 28.70 505.40 13.17 12.59
01/20 14:00 0.00 ---- 626.83 604177 482.25 34 73 44.55 171.90 3.50 29.00 518.10 13.17 12.76
01/20 15:00 0.00 ---- 626.81 603941 482.23 4 73 46.11 156.10 3.40 29.96 503.30 13.17 12.77
01/20 16:00 0.00 ---- 626.83 604177 482.23 0 73 48.43 133.00 3.40 29.45 337.10 13.16 12.77
01/20 17:00 0.00 ---- 626.84 604296 482.22 0 73 48.92 106.30 3.30 29.76 100.40 13.17 12.76
01/20 18:00 0.00 ---- 626.82 604059 482.70 0 73 46.81 113.80 2.10 32.18 5.00 13.16 12.77
01/20 19:00 0.00 ---- 626.79 603705 486.63 0 3829 44.08 331.20 1.20 37.20 1.80 13.17 12.77
01/20 20:00 0.00 ---- 626.77 603469 486.82 0 3829 42.91 70.10 1.60 39.19 2.50 13.17 12.77
01/20 21:00 0.00 ---- 626.75 603233 486.76 0 3829 41.61 52.20 1.60 42.76 2.60 13.17 12.77
01/20 22:00 0.00 ---- 626.70 602643 486.80 0 3829 42.93 281.70 1.80 46.06 2.10 13.17 12.76
01/20 23:00 0.00 ---- 626.70 602643 ---- ---- ---- 44.24 208.70 1.60 47.32 1.90 13.16 12.77
Data processed at Wed 21Jan2026 05:31 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting early 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. When this migration completes you will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
TENK.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
TENK.Precip-Inc Alt.Total.1Hour.1Hour.Ccp-Rev
TENK.Elev.Inst.1Hour.0.Ccp-Rev
TENK.Stor.Inst.1Hour.0.Ccp-Rev
TENK.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
TENK.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
TENK.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
TENK.Temp-Air.Inst.1Hour.0.Ccp-Rev
TENK.Dir-Wind.Inst.1Hour.0.Ccp-Rev
TENK.Speed-Wind.Inst.1Hour.0.Ccp-Rev
TENK.%-Humidity.Inst.1Hour.0.Ccp-Rev
TENK.Irrad.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.