TENO2: Tenkiller Lake

                                SHEF ID:       TENO2     Tenkiller Lake
STATION TYPE: Reservoir
Flood Pool: Bottom = 632.00, Top = 667.00

PRECIP PRECIP(A) ELEVATION STORAGE TW-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in in ft ac-ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
12/29 00:00 0.00 ---- 629.66 638526 482.22 341 78 30.83 228.90 3.70 54.54 5.50 13.18 12.75
12/29 01:00 0.00 ---- 629.68 638774 482.22 345 78 30.16 230.90 3.10 52.94 6.10 13.18 12.75
12/29 02:00 0.00 ---- 629.69 638897 482.22 425 78 31.15 218.80 2.30 56.55 6.70 13.18 12.73
12/29 03:00 0.00 ---- 629.69 638897 482.22 422 78 29.62 222.00 1.80 58.67 6.40 13.18 12.75
12/29 04:00 0.00 ---- 629.70 639021 482.22 206 78 27.64 245.80 0.80 63.70 3.20 13.18 12.76
12/29 05:00 0.00 ---- 629.70 639021 482.22 96 78 27.81 248.90 1.40 66.46 4.10 13.18 12.76
12/29 06:00 0.00 ---- 629.71 639145 482.71 395 604 30.51 222.00 4.50 55.98 4.30 13.18 12.74
12/29 07:00 0.00 ---- 629.66 638526 486.81 308 3568 30.67 218.60 5.50 56.57 3.10 13.18 12.77
12/29 08:00 0.00 ---- 629.67 638650 486.85 336 3750 29.08 221.80 4.80 58.18 6.80 13.18 12.74
12/29 09:00 0.00 ---- 629.63 638154 486.90 336 3750 29.53 216.20 5.80 54.98 175.90 13.18 12.75
12/29 10:00 0.00 ---- 629.61 637906 486.90 341 3568 30.25 212.50 6.00 51.76 369.40 13.18 12.73
12/29 11:00 0.00 ---- 629.59 637658 482.68 42 341 31.96 206.40 4.90 46.98 510.20 13.18 12.76
12/29 12:00 0.00 ---- 629.58 637534 482.30 42 78 34.45 185.50 4.50 44.60 593.60 13.18 12.76
12/29 13:00 ---- ---- 629.59 637658 482.26 9 78 36.05 210.00 4.80 41.65 382.60 13.18 ----
12/29 14:00 ---- ---- 629.60 637782 482.24 24 78 40.19 212.10 4.30 42.47 559.40 13.18 12.75
12/29 15:00 0.00 ---- 629.58 637534 482.23 34 78 42.46 210.40 4.20 42.07 435.40 13.18 12.76
12/29 16:00 0.00 ---- 629.60 637782 482.23 236 78 42.15 216.00 3.80 42.61 262.20 13.17 12.76
12/29 17:00 0.00 ---- 629.58 637534 482.70 236 341 41.07 224.70 3.60 44.07 52.70 13.18 12.75
12/29 18:00 0.00 ---- 629.57 637410 486.76 237 3659 43.09 253.00 2.20 53.87 6.30 13.18 12.75
12/29 19:00 0.00 ---- 629.55 637163 486.85 545 3750 34.02 291.30 0.90 55.80 4.20 13.17 12.75
12/29 20:00 0.00 ---- 629.52 636791 486.79 583 3750 32.23 298.00 1.20 67.61 5.40 13.18 12.75
12/29 21:00 0.00 ---- 629.51 636667 486.90 700 3568 33.17 277.20 1.90 62.00 5.90 13.18 12.76
12/29 22:00 0.00 ---- 629.51 636667 482.68 483 341 32.76 241.70 2.70 57.05 5.90 13.18 12.76
12/29 23:00 0.00 ---- 629.49 636419 482.30 ---- ---- 32.25 224.20 2.70 56.35 5.60 13.18 12.75
Data processed at Tue 30Dec2025 05:31 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting early 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. When this migration completes you will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
TENK.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
TENK.Precip-Inc Alt.Total.1Hour.1Hour.Ccp-Rev
TENK.Elev.Inst.1Hour.0.Ccp-Rev
TENK.Stor.Inst.1Hour.0.Ccp-Rev
TENK.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
TENK.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
TENK.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
TENK.Temp-Air.Inst.1Hour.0.Ccp-Rev
TENK.Dir-Wind.Inst.1Hour.0.Ccp-Rev
TENK.Speed-Wind.Inst.1Hour.0.Ccp-Rev
TENK.%-Humidity.Inst.1Hour.0.Ccp-Rev
TENK.Irrad.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.