TENO2: Tenkiller Lake

                                SHEF ID:       TENO2     Tenkiller Lake
STATION TYPE: Reservoir
Flood Pool: Bottom = 632.00, Top = 667.00

PRECIP PRECIP(A) ELEVATION STORAGE TW-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in in ft ac-ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
11/06 00:00 0.00 ---- 633.27 685477 483.65 543 565 55.17 160.70 0.50 94.69 3.00 13.18 12.74
11/06 01:00 0.00 ---- 633.27 685477 483.66 539 565 54.07 163.20 0.40 95.30 2.60 13.18 12.76
11/06 02:00 0.00 ---- 633.27 685477 483.66 533 565 53.06 180.90 0.50 96.37 3.20 13.18 12.75
11/06 03:00 0.00 ---- 633.27 685477 483.66 525 565 52.88 188.70 0.50 97.53 3.00 13.18 12.74
11/06 04:00 0.00 ---- 633.27 685477 483.67 517 565 54.32 198.10 0.20 97.52 1.30 13.18 12.75
11/06 05:00 0.00 ---- 633.27 685477 483.66 410 565 56.46 189.50 0.20 95.80 1.10 13.18 12.76
11/06 06:00 0.00 ---- 633.27 685477 483.66 303 565 57.13 235.80 0.40 95.86 2.50 13.17 12.75
11/06 07:00 0.00 ---- 633.27 685477 483.66 292 565 59.31 276.60 0.40 89.56 2.60 13.18 12.76
11/06 08:00 0.00 ---- 633.26 685345 483.65 284 565 62.26 89.70 1.10 77.32 17.60 13.18 12.74
11/06 09:00 0.00 ---- 633.26 685345 483.66 277 565 63.73 79.10 1.40 75.25 88.10 13.18 12.83
11/06 10:00 0.00 ---- 633.26 685345 483.65 277 565 66.07 89.70 3.10 69.79 358.70 13.18 12.76
11/06 11:00 0.00 ---- 633.26 685345 483.67 277 565 69.69 95.80 4.00 64.19 607.40 13.18 12.74
11/06 12:00 0.00 ---- 633.26 685345 483.67 536 565 72.28 108.60 4.50 60.73 673.00 13.18 12.74
11/06 13:00 0.00 ---- 633.25 685213 483.78 617 565 74.68 139.50 4.30 59.23 376.10 13.18 12.76
11/06 14:00 0.00 ---- 633.26 685345 485.05 525 565 77.47 130.90 4.70 56.14 599.00 13.18 12.75
11/06 15:00 0.00 ---- 633.26 685345 484.26 525 1063 78.62 106.90 4.80 52.30 468.50 13.18 12.74
11/06 16:00 0.00 ---- 633.24 685081 483.01 525 607 77.63 142.20 3.40 54.20 170.40 13.18 12.75
11/06 17:00 0.00 ---- 633.24 685081 485.47 221 1804 76.60 150.40 2.40 57.47 60.00 13.18 12.75
11/06 18:00 0.00 ---- 633.23 684950 486.90 73 3724 74.50 316.60 0.80 63.97 6.20 13.18 12.74
11/06 19:00 0.00 ---- 633.20 684554 486.15 100 3210 73.02 308.00 1.30 69.08 5.60 13.18 12.86
11/06 20:00 0.00 ---- 633.21 684686 482.90 422 150 72.23 280.20 1.50 70.89 7.90 13.17 12.74
11/06 21:00 0.00 ---- 633.20 684554 482.69 449 150 70.86 313.50 1.20 73.48 5.10 13.18 12.74
11/06 22:00 0.00 ---- 633.21 684686 482.66 1019 150 69.35 354.30 0.60 76.71 2.30 13.17 12.74
11/06 23:00 0.00 ---- 633.22 684818 482.64 ---- ---- 68.27 54.40 0.90 79.19 6.10 13.18 12.74
Data processed at Fri 07Nov2025 05:31 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting January 1st, 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. You will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
TENK.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
TENK.Precip-Inc Alt.Total.1Hour.1Hour.Ccp-Rev
TENK.Elev.Inst.1Hour.0.Ccp-Rev
TENK.Stor.Inst.1Hour.0.Ccp-Rev
TENK.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
TENK.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
TENK.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
TENK.Temp-Air.Inst.1Hour.0.Ccp-Rev
TENK.Dir-Wind.Inst.1Hour.0.Ccp-Rev
TENK.Speed-Wind.Inst.1Hour.0.Ccp-Rev
TENK.%-Humidity.Inst.1Hour.0.Ccp-Rev
TENK.Irrad.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.