TENO2: Tenkiller Lake

                                SHEF ID:       TENO2     Tenkiller Lake
STATION TYPE: Reservoir
Flood Pool: Bottom = 632.00, Top = 667.00

PRECIP PRECIP(A) ELEVATION STORAGE TW-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in in ft ac-ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
04/25 00:00 0.00 ---- 638.40 755186 491.82 5053 12163 58.87 255.60 1.20 100.31 4.80 13.18 12.74
04/25 01:00 0.00 ---- 638.35 754487 491.83 5051 12161 58.60 254.40 1.30 100.31 5.70 13.18 12.73
04/25 02:00 0.00 ---- 638.30 753787 491.86 4710 12159 58.32 256.70 1.30 100.31 5.80 13.18 12.73
04/25 03:00 0.00 ---- 638.27 753368 491.88 4708 12157 58.21 264.10 0.90 100.31 4.60 13.18 12.74
04/25 04:00 0.00 ---- 638.21 752528 491.85 5044 12155 58.23 261.90 1.20 100.31 6.30 13.18 12.73
04/25 05:00 0.00 ---- 638.18 752108 491.86 4365 12152 59.14 275.60 0.90 100.31 4.20 13.18 12.73
04/25 06:00 0.00 ---- 638.14 751549 491.86 4702 12151 61.86 67.00 2.30 100.30 7.10 13.18 12.73
04/25 07:00 0.00 ---- 638.07 750569 491.82 5377 12148 61.77 196.60 1.80 100.30 7.20 13.18 12.86
04/25 08:00 0.01 ---- 638.05 750290 491.85 4044 12146 62.80 94.60 2.10 100.24 42.60 13.18 12.74
04/25 09:00 0.00 ---- 638.01 749730 491.83 4727 12145 62.20 247.70 1.10 100.19 248.50 13.18 12.73
04/25 10:00 0.00 ---- 637.94 748760 491.82 5756 12142 64.67 136.50 0.60 97.01 249.10 13.18 12.73
04/25 11:00 0.00 ---- 637.92 748484 491.82 4423 12140 64.40 230.40 0.90 96.94 284.00 13.18 12.74
04/25 12:00 0.00 ---- 637.88 747930 491.82 4436 12139 66.92 141.20 0.20 90.83 541.10 13.18 12.76
04/25 13:00 0.00 ---- 637.82 747101 491.82 5108 12136 69.01 143.20 0.50 84.96 720.90 13.18 12.73
04/25 14:00 0.00 ---- 637.78 746547 491.86 3767 12134 71.47 136.60 1.70 75.73 1020.90 13.18 12.73
04/25 15:00 0.00 ---- 637.73 745856 491.82 4099 12132 72.37 98.90 5.50 69.85 934.70 13.18 12.74
04/25 16:00 0.00 ---- 637.67 745026 491.81 4432 12129 73.27 99.50 4.80 67.91 802.10 13.18 12.73
04/25 17:00 0.00 ---- 637.64 744611 491.82 4095 12127 72.41 136.70 1.40 69.33 668.50 13.18 12.73
04/25 18:00 0.00 ---- 637.59 743920 491.82 4092 12125 71.20 233.00 0.70 71.25 448.30 13.18 12.74
04/25 19:00 0.00 ---- 637.54 743228 491.82 5094 12123 67.93 246.60 1.00 78.80 130.60 13.18 12.74
04/25 20:00 0.00 ---- 637.49 742537 491.84 4423 12120 63.36 249.40 1.80 91.37 9.90 13.18 12.74
04/25 21:00 0.00 ---- 637.46 742122 491.84 5091 12119 60.62 240.50 1.50 99.21 4.10 13.18 12.74
04/25 22:00 0.00 ---- 637.41 741430 491.85 4420 12117 59.97 239.20 1.40 100.30 4.70 13.18 12.74
04/25 23:00 0.00 ---- 637.36 740739 491.82 ---- ---- 60.21 246.60 1.40 100.29 5.40 13.18 12.74
Data processed at Sat 26Apr2025 04:31 GMT

Parsing this webpage?

Checkout our new Data API! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
TENK.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
TENK.Precip-Inc Alt.Total.1Hour.1Hour.Ccp-Rev
TENK.Elev.Inst.1Hour.0.Ccp-Rev
TENK.Stor.Inst.1Hour.0.Ccp-Rev
TENK.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
TENK.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
TENK.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
TENK.Temp-Air.Inst.1Hour.0.Ccp-Rev
TENK.Dir-Wind.Inst.1Hour.0.Ccp-Rev
TENK.Speed-Wind.Inst.1Hour.0.Ccp-Rev
TENK.%-Humidity.Inst.1Hour.0.Ccp-Rev
TENK.Irrad.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery.Inst.1Hour.0.Ccp-Rev
TENK.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.