PENO2: Grand Lake O' The Cherokees, Pensacola Dm

                                SHEF ID:       PENO2     Pensacola (Grand Lake)
STATION TYPE: RESERVOIR
Flood Pool: Bottom = 743.00, Top = 755.00

PRECIP ELEVATION STORAGE INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in ft ac-ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
09/14 00:00 0.00 742.95 1347428 12 326 68.31 33.05 1.95 74.17 0.00 12.66 12.41
09/14 01:00 0.00 742.96 1347851 10 326 68.52 29.50 1.13 71.71 0.00 12.65 12.41
09/14 02:00 0.00 742.95 1347428 6 325 68.38 57.10 1.33 67.06 0.00 12.64 12.41
09/14 03:00 0.00 742.96 1347851 5 0 68.59 82.11 1.37 63.39 0.00 12.62 12.41
09/14 04:00 0.00 742.95 1347428 6 217 68.20 53.09 1.62 62.57 0.00 12.61 12.41
09/14 05:00 0.00 742.95 1347428 8 325 67.91 60.06 1.03 62.89 0.00 12.60 12.33
09/14 06:00 0.00 742.95 1347428 7 325 66.97 57.04 1.21 64.60 0.00 12.59 12.33
09/14 07:00 0.00 742.95 1347428 7 325 66.60 66.97 1.17 65.57 0.00 12.58 12.33
09/14 08:00 0.00 742.93 1346583 5 325 66.61 76.00 0.83 64.77 10.39 12.57 12.33
09/14 09:00 0.00 742.94 1347006 5 326 67.48 138.98 0.97 62.93 115.22 12.57 12.33
09/14 10:00 0.00 742.93 1346583 3 325 69.35 63.41 1.03 64.07 175.32 12.56 12.33
09/14 11:00 0.00 742.93 1346583 3 108 72.27 13.06 1.26 60.71 360.94 12.56 12.33
09/14 12:00 0.00 742.94 1347006 3 0 75.33 7.71 2.12 52.51 632.83 12.56 12.33
09/14 13:00 0.00 742.95 1347428 3 0 77.22 18.62 2.31 48.19 693.08 12.57 12.33
09/14 14:00 0.00 742.95 1347428 0 0 78.26 14.17 3.94 46.69 719.61 13.28 13.05
09/14 15:00 0.00 742.95 1347428 0 217 79.36 22.03 2.59 45.72 620.96 13.30 13.05
09/14 16:00 0.00 742.95 1347428 0 217 80.11 12.64 3.22 45.29 572.67 13.32 13.05
09/14 17:00 0.00 742.95 1347428 0 325 80.78 16.56 3.00 42.25 423.30 13.34 13.05
09/14 18:00 0.00 742.96 1347851 0 324 80.92 16.94 3.79 42.58 261.58 13.42 12.97
09/14 19:00 0.00 742.96 1347851 0 324 79.41 22.36 3.10 44.43 19.19 13.30 12.89
09/14 20:00 0.00 742.95 1347428 0 324 76.23 24.53 1.64 52.80 0.00 13.46 12.89
09/14 21:00 0.00 742.95 1347428 0 325 73.08 31.32 2.15 57.60 0.00 13.47 12.89
09/14 22:00 0.00 742.95 1347428 0 325 70.92 32.57 2.50 60.24 0.00 13.50 12.89
09/14 23:00 0.00 742.93 1346583 ---- ---- 69.71 37.66 1.17 61.45 0.00 13.11 12.97
Data processed at Fri 15Sep2023 04:38 GMT

Parsing this webpage?

Checkout our new Data API! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
PENS.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
PENS.Elev.Inst.1Hour.0.Ccp-Rev
PENS.Stor.Inst.1Hour.0.Ccp-Rev
PENS.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
PENS.Flow-Res Out.Inst.1Hour.0.Rev-Regi-Flowgroup
PENS.Temp-Air.Inst.1Hour.0.Ccp-Rev
PENS.Dir-Wind.Inst.1Hour.0.Ccp-Rev
PENS.Speed-Wind.Inst.1Hour.0.Ccp-Rev
PENS.%-Humidity.Inst.1Hour.0.Ccp-Rev
PENS.Irrad.Inst.1Hour.0.Ccp-Rev
PENS.Volt-Battery.Inst.1Hour.0.Ccp-Rev
PENS.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.