PCLO2: Pine Creek Lake

                                SHEF ID:       PCLO2     Pine Creek Lake
STATION TYPE: RESERVOIR
Flood Pool: Bottom = 438.00, Top = 480.00

PRECIP ELEVATION STORAGE TW-ELEV INFLOW RELEASE STAGE(2) AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in ft ac-ft ft cfs cfs ft F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
11/25 00:00 0.00 437.53 39074 383.92 2352 144 ---- 57.54 215.30 1.90 100.09 0.00 13.10 12.26
11/25 01:00 0.00 437.59 39256 383.92 2353 144 ---- 57.60 244.40 1.70 100.09 0.00 13.11 12.24
11/25 02:00 0.00 437.64 39408 383.92 2205 144 ---- 57.79 256.70 3.70 100.09 0.00 13.11 11.93
11/25 03:00 0.00 437.69 39560 383.92 1911 144 ---- 58.14 255.90 4.40 99.14 0.00 13.11 11.94
11/25 04:00 0.00 437.73 39682 383.92 1837 144 ---- 58.32 261.80 4.00 97.29 0.00 13.11 12.22
11/25 05:00 0.00 437.77 39804 383.92 1764 144 ---- 58.23 258.20 3.60 96.20 0.00 13.11 12.23
11/25 06:00 0.00 437.82 39956 383.92 1690 144 ---- 57.20 218.30 1.40 97.71 0.00 13.10 12.01
11/25 07:00 0.00 437.86 40078 383.92 1690 144 ---- 56.55 251.50 0.60 99.23 0.00 13.11 12.13
11/25 08:00 0.00 437.90 40199 383.92 1691 145 ---- 57.06 298.90 2.70 95.59 1.70 13.11 12.31
11/25 09:00 0.00 437.94 40321 383.92 1627 145 ---- 57.54 306.20 3.10 92.62 42.90 13.20 12.04
11/25 10:00 0.00 437.98 40443 383.92 1646 145 ---- 58.24 256.50 3.20 91.16 104.70 13.90 12.13
11/25 11:00 0.00 438.02 40568 383.93 1666 145 ---- 60.91 278.20 2.10 81.92 453.40 14.27 13.10
11/25 12:00 0.00 438.06 40698 383.93 1685 145 ---- 61.56 271.00 4.00 77.95 189.30 13.87 12.98
11/25 13:00 0.00 438.10 40828 383.93 1705 145 ---- 62.19 274.10 6.20 76.62 318.50 13.88 12.86
11/25 14:00 0.00 438.14 40958 383.92 1636 145 ---- 61.70 305.20 6.40 74.46 174.00 13.84 12.80
11/25 15:00 0.00 438.18 41087 383.93 1636 145 ---- 61.12 318.90 8.10 72.14 163.00 13.84 12.79
11/25 16:00 0.00 438.21 41184 383.92 1557 145 ---- 60.89 305.00 4.50 73.17 90.80 13.66 12.71
11/25 17:00 0.00 438.25 41314 383.92 1558 145 ---- 61.79 313.00 2.80 71.62 86.00 13.37 12.71
11/25 18:00 0.00 438.28 41411 383.92 1479 145 ---- 58.84 291.10 2.00 82.38 0.00 13.11 12.23
11/25 19:00 0.00 438.32 41541 383.93 1479 145 ---- 54.72 192.80 0.80 94.90 0.00 13.11 12.05
11/25 20:00 0.00 438.35 41638 383.93 1479 145 ---- 54.23 325.40 0.90 96.85 0.00 13.11 12.31
11/25 21:00 0.00 438.38 41736 383.92 1479 145 ---- 53.42 346.80 3.70 98.91 0.00 13.11 12.01
11/25 22:00 0.00 438.42 41865 383.92 1558 145 ---- 53.85 342.30 6.50 95.12 0.00 13.11 12.01
11/25 23:00 0.00 438.45 41963 383.92 ---- ---- ---- 54.37 331.00 7.40 87.60 0.00 13.11 12.24
Data processed at Wed 26Nov2025 05:09 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting January 1st, 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. You will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
PINE.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
PINE.Elev.Inst.1Hour.0.Ccp-Rev
PINE.Stor.Inst.1Hour.0.Ccp-Rev
PINE.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
PINE.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
PINE.Flow-Res Out.Inst.1Hour.0.Rev-Regi-Flowgroup
PINE.Stage-Alt.Inst.1Hour.0.Ccp-Rev
PINE.Temp-Air.Inst.1Hour.0.Ccp-Rev
PINE.Dir-Wind.Inst.1Hour.0.Ccp-Rev
PINE.Speed-Wind.Inst.1Hour.0.Ccp-Rev
PINE.%-Humidity.Inst.1Hour.0.Ccp-Rev
PINE.Irrad.Inst.1Hour.0.Ccp-Rev
PINE.Volt-Battery.Inst.1Hour.0.Ccp-Rev
PINE.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.