PRECIP ELEVATION STORAGE TW-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in ft ac-ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
06/30 00:00 0.05 619.97 210967 561.95 1712 153 77.18 327.10 2.30 89.86 0.00 13.16 12.81
06/30 01:00 0.04 620.06 211983 561.52 1311 153 76.73 11.00 3.50 91.22 0.00 13.16 12.81
06/30 02:00 0.01 619.98 211078 561.19 2458 153 76.68 7.60 3.40 91.20 0.00 13.16 12.81
06/30 03:00 0.00 619.91 210300 560.93 3877 153 76.41 287.00 1.10 93.87 0.00 13.16 12.81
06/30 04:00 0.00 619.90 210189 560.72 4755 153 75.99 306.80 1.10 94.86 0.00 13.15 12.81
06/30 05:00 0.00 619.87 209856 560.54 4669 153 75.58 254.40 2.10 97.25 0.00 13.16 12.81
06/30 06:00 0.00 619.82 209300 560.40 4790 153 75.94 46.40 1.70 97.34 0.00 13.16 12.81
06/30 07:00 0.00 619.81 209189 560.27 3127 152 76.53 330.00 1.50 96.06 11.90 13.16 12.81
06/30 08:00 0.00 619.83 209411 560.16 2274 152 77.04 336.90 2.30 95.45 59.80 13.15 12.81
06/30 09:00 0.00 619.84 209522 560.06 1421 153 77.72 357.20 3.80 93.75 143.80 13.16 12.81
06/30 10:00 0.00 619.86 209745 559.97 1465 153 78.42 345.20 3.70 91.54 127.00 13.16 12.81
06/30 11:00 0.00 619.86 209745 559.89 955 153 78.15 355.30 5.00 91.59 142.40 13.16 12.81
06/30 12:00 0.00 619.86 209745 559.83 1465 153 79.05 351.50 4.80 89.43 331.40 13.16 12.81
06/30 13:00 0.00 619.86 209745 559.76 896 153 81.28 355.20 4.70 84.00 696.40 13.16 12.81
06/30 14:00 0.00 619.89 210078 559.70 2002 153 82.26 30.50 5.50 82.51 588.60 13.16 12.81
06/30 15:00 0.00 619.88 209967 559.60 3046 153 84.70 11.00 4.50 76.14 743.30 13.16 12.81
06/30 16:00 0.00 619.85 209633 563.27 4413 9873 87.03 353.00 5.00 70.51 696.40 13.16 12.81
06/30 17:00 0.00 619.77 208745 564.92 3656 16352 87.46 347.00 6.80 68.51 511.50 13.16 12.81
06/30 18:00 0.00 619.75 208522 564.61 3693 9872 86.16 21.70 7.10 73.22 500.30 13.16 12.81
06/30 19:00 0.00 619.80 209078 562.99 3894 152 86.22 21.00 7.00 74.08 288.70 13.16 12.81
06/30 20:00 0.00 619.75 208522 562.21 3097 152 86.00 39.70 7.80 75.17 122.00 13.16 12.81
06/30 21:00 0.00 619.80 209078 561.71 3037 152 84.94 44.50 5.30 77.92 7.50 13.16 12.81
06/30 22:00 0.00 619.81 209189 561.33 2246 152 83.43 48.70 5.10 80.97 0.00 13.16 12.81
06/30 23:00 0.00 619.73 208300 561.04 ---- ---- 81.93 36.10 4.70 83.37 0.00 13.16 12.81
Data processed at Mon 01Jul2024 04:02 GMT

Parsing this webpage?

Checkout our new Data API! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
HUDS.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
HUDS.Elev.Inst.1Hour.0.Ccp-Rev
HUDS.Stor.Inst.1Hour.0.Ccp-Rev
HUDS.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
HUDS.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
HUDS.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
HUDS.Temp-Air.Inst.1Hour.0.Ccp-Rev
HUDS.Dir-Wind.Inst.1Hour.0.Ccp-Rev
HUDS.Speed-Wind.Inst.1Hour.0.Ccp-Rev
HUDS.%-Humidity.Inst.1Hour.0.Ccp-Rev
HUDS.Irrad.Inst.1Hour.0.Ccp-Rev
HUDS.Volt-Battery.Inst.1Hour.0.Ccp-Rev
HUDS.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.