MAYO2: W. D. Mayo Lock And Dam (L&D 14)

                                SHEF ID:       MAYO2     W.D. Mayo LD14
STATION TYPE: NAVIGATION LOCK
Navigation Pool: Bottom = 411.00, Top = 413.00

PRECIP ELEVATION STORAGE TW-ELEV LOCK-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in ft ac-ft ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
03/10 00:00 0.00 412.21 34475 392.99 ---- 25092 24828 64.38 20.40 1.60 98.56 0.00 13.58 13.33
03/10 01:00 0.00 412.24 34556 392.95 ---- 24999 24675 63.88 9.70 1.80 100.08 0.00 13.58 13.32
03/10 02:00 0.00 412.23 34529 392.94 ---- 24971 24681 63.30 4.80 2.20 100.09 0.00 13.58 13.36
03/10 03:00 0.00 412.23 34529 393.00 ---- 24877 24678 63.37 8.60 2.30 100.09 0.00 13.58 13.34
03/10 04:00 0.00 412.24 34556 392.96 ---- 24748 24681 62.98 12.60 1.50 100.08 0.00 13.58 13.33
03/10 05:00 0.00 412.24 34556 392.94 ---- 24816 24685 62.92 18.80 1.30 100.08 0.00 13.58 13.36
03/10 06:00 0.00 412.25 34584 392.99 ---- 24686 24688 62.47 141.10 0.90 100.08 0.00 13.58 13.34
03/10 07:00 0.00 412.25 34584 393.02 ---- 24818 24691 62.74 331.20 0.60 100.08 0.00 13.58 13.35
03/10 08:00 0.00 412.23 34529 393.01 ---- 24887 24685 63.84 104.70 2.00 100.08 0.00 13.58 13.36
03/10 09:00 0.00 412.26 34611 393.05 ---- 24957 24688 66.04 163.30 1.40 99.13 5.30 13.58 13.35
03/10 10:00 0.00 412.27 34638 393.13 ---- 24895 24700 71.40 146.90 4.50 86.88 50.80 13.58 13.36
03/10 11:00 0.00 412.29 34692 393.08 ---- 25098 24709 72.21 145.70 4.60 82.24 49.90 13.58 13.34
03/10 12:00 0.00 412.28 34665 393.25 ---- 25171 24713 73.94 182.50 5.90 77.48 76.40 13.59 13.42
03/10 13:00 0.00 412.29 34692 393.08 ---- 24519 24713 75.34 170.10 6.00 73.41 264.00 13.58 13.21
03/10 14:00 0.00 412.33 34800 393.09 ---- 24713 24728 76.57 164.20 7.20 67.76 292.90 13.59 13.39
03/10 15:00 0.00 412.24 34556 393.02 ---- 24912 24713 76.96 171.00 8.80 67.23 283.80 13.58 13.32
03/10 16:00 0.00 412.29 34692 393.14 ---- 24981 24700 76.32 164.80 7.50 71.18 153.10 13.58 13.33
03/10 17:00 0.00 412.31 34746 393.12 ---- 24590 24722 77.38 165.70 9.30 68.24 226.40 13.58 13.32
03/10 18:00 0.00 412.33 34800 393.14 ---- 25447 24734 77.86 158.50 9.80 65.35 252.80 13.59 13.33
03/10 19:00 0.00 412.31 34746 393.08 ---- 24799 24734 77.92 157.00 6.90 66.24 100.30 13.59 13.33
03/10 20:00 0.00 412.35 34854 393.14 ---- 22334 24741 75.31 146.60 3.50 71.88 0.00 13.59 13.32
03/10 21:00 0.00 412.30 34719 393.21 ---- 21876 24737 74.61 157.90 1.80 73.07 0.00 13.59 13.41
03/10 22:00 0.00 411.94 33764 392.17 ---- 17660 24608 73.29 114.40 1.50 76.51 0.00 13.58 13.33
03/10 23:00 0.00 411.86 33573 391.99 ---- ---- ---- 73.13 138.30 3.40 77.80 0.00 13.58 13.34
Data processed at Wed 11Mar2026 04:31 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting early 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. When this migration completes you will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
WDMA.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
WDMA.Elev.Inst.1Hour.0.Ccp-Rev
WDMA.Stor.Inst.1Hour.0.Ccp-Rev
WDMA.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
WDMA.Elev-Lock Chamber.Inst.1Hour.0.Ccp-Rev
WDMA.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
WDMA.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
WDMA.Temp-Air.Inst.1Hour.0.Ccp-Rev
WDMA.Dir-Wind.Inst.1Hour.0.Ccp-Rev
WDMA.Speed-Wind.Inst.1Hour.0.Ccp-Rev
WDMA.%-Humidity.Inst.1Hour.0.Ccp-Rev
WDMA.Irrad.Inst.1Hour.0.Ccp-Rev
WDMA.Volt-Battery.Inst.1Hour.0.Ccp-Rev
WDMA.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.