MAYO2: W. D. Mayo Lock And Dam (L&D 14)

                                SHEF ID:       MAYO2     W.D. Mayo LD14
STATION TYPE: NAVIGATION LOCK
Navigation Pool: Bottom = 411.00, Top = 413.00

PRECIP ELEVATION STORAGE TW-ELEV LOCK-ELEV INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in ft ac-ft ft ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
12/18 00:00 0.00 412.12 34232 392.00 ---- 7261 7202 55.40 130.40 3.00 100.10 0.00 12.82 12.24
12/18 01:00 0.00 412.12 34232 392.03 ---- 7455 7184 58.46 167.10 1.80 98.44 0.00 12.81 12.23
12/18 02:00 0.00 412.16 34340 391.96 ---- 6928 7188 60.84 175.40 5.10 93.06 0.00 12.79 12.21
12/18 03:00 0.00 412.16 34340 392.00 ---- 7121 7191 61.65 158.80 7.60 89.21 0.00 12.78 12.19
12/18 04:00 0.00 412.11 34205 391.92 ---- 7318 7187 62.56 168.80 7.60 84.52 0.00 12.75 12.19
12/18 05:00 0.00 412.11 34205 391.83 ---- 7778 7182 62.13 165.00 5.90 86.51 0.00 12.74 12.17
12/18 06:00 0.00 412.14 34286 391.88 ---- 9556 7185 62.10 171.60 5.50 86.36 0.00 12.73 12.14
12/18 07:00 0.00 412.25 34584 392.36 ---- 11401 7198 61.47 219.70 1.90 87.72 0.00 12.71 12.13
12/18 08:00 0.00 412.28 34665 392.42 ---- 13116 15098 61.03 199.70 2.10 86.72 5.80 12.74 12.13
12/18 09:00 0.01 412.27 34638 391.82 ---- 15031 15102 61.95 222.60 2.90 85.41 13.60 12.74 12.15
12/18 10:00 0.05 412.29 34692 391.69 ---- 15372 15104 60.51 254.10 4.70 91.39 21.90 12.97 12.12
12/18 11:00 0.01 412.37 34908 392.10 ---- 15572 15123 61.52 268.70 7.90 82.02 132.70 13.46 12.85
12/18 12:00 0.00 412.29 34692 392.23 ---- 15116 15123 60.31 315.80 12.90 60.13 179.20 13.61 12.93
12/18 13:00 0.00 412.35 34854 391.88 ---- 16368 15119 57.42 335.10 15.20 51.90 338.30 13.62 12.83
12/18 14:00 0.00 412.27 34638 391.84 ---- 16053 15115 57.25 332.70 13.00 33.39 177.90 13.49 12.70
12/18 15:00 0.00 412.48 35206 393.22 ---- 16788 15139 58.53 313.20 10.40 32.46 309.20 13.62 12.73
12/18 16:00 0.00 412.51 35287 393.13 ---- 15885 15185 60.12 305.00 9.70 26.23 210.20 13.62 12.80
12/18 17:00 0.00 412.54 35369 393.00 ---- 16354 15196 59.76 308.80 11.30 18.14 56.80 13.02 12.61
12/18 18:00 0.00 412.46 35152 393.08 ---- 14918 15187 57.27 309.70 9.70 18.35 0.00 12.91 12.37
12/18 19:00 0.00 412.45 35125 393.03 ---- 14454 15170 55.83 307.60 12.00 19.49 0.00 12.88 12.33
12/18 20:00 0.00 412.44 35098 393.05 ---- 14051 15166 54.05 304.40 10.90 20.70 0.00 12.86 12.36
12/18 21:00 0.00 412.40 34990 393.00 ---- 14307 15156 52.56 322.60 13.00 22.11 0.00 12.85 12.27
12/18 22:00 0.00 412.37 34908 393.11 ---- 14233 15143 50.74 335.90 12.60 25.36 0.00 12.83 12.27
12/18 23:00 0.00 412.32 34773 393.04 ---- ---- ---- 48.22 341.40 13.60 27.72 0.00 12.81 12.25
Data processed at Fri 19Dec2025 05:31 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting January 1st, 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. You will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
WDMA.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
WDMA.Elev.Inst.1Hour.0.Ccp-Rev
WDMA.Stor.Inst.1Hour.0.Ccp-Rev
WDMA.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
WDMA.Elev-Lock Chamber.Inst.1Hour.0.Ccp-Rev
WDMA.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
WDMA.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
WDMA.Temp-Air.Inst.1Hour.0.Ccp-Rev
WDMA.Dir-Wind.Inst.1Hour.0.Ccp-Rev
WDMA.Speed-Wind.Inst.1Hour.0.Ccp-Rev
WDMA.%-Humidity.Inst.1Hour.0.Ccp-Rev
WDMA.Irrad.Inst.1Hour.0.Ccp-Rev
WDMA.Volt-Battery.Inst.1Hour.0.Ccp-Rev
WDMA.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.