KAWO2: Kaw Lake

                                SHEF ID:       KAWO2     Kaw Lake
STATION TYPE: RESERVOIR
Flood Pool: Bottom = 1010.00, Top = 1044.50

PRECIP ELEVATION STORAGE TW-ELEV INFLOW RELEASE STAGE RIV-FLOW AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in ft ac-ft ft cfs cfs ft cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
12/13 00:00 0.00 1011.65 368405 928.19 1740 3567 4.53 3949 38.23 32.20 11.70 80.81 0.00 12.88 12.55
12/13 01:00 0.00 1011.65 368405 928.19 2079 3566 4.53 3949 36.32 30.50 16.20 89.44 0.00 12.86 12.53
12/13 02:00 0.00 1011.63 368102 928.19 1380 3565 4.53 3949 34.90 41.10 15.60 91.95 0.00 12.84 12.51
12/13 03:00 0.00 1011.62 367951 928.19 1379 3563 4.53 3949 33.48 48.10 12.70 93.26 0.00 12.82 12.50
12/13 04:00 0.00 1011.60 367649 928.19 1738 3561 4.53 3949 32.16 58.00 11.10 94.99 0.00 12.80 12.48
12/13 05:00 0.00 1011.59 367498 928.19 1738 3559 4.53 3949 31.06 53.80 10.10 96.67 0.00 12.77 12.46
12/13 06:00 0.00 1011.60 367649 928.19 1741 3559 4.53 3949 31.46 40.60 12.00 98.56 0.00 12.74 12.43
12/13 07:00 0.00 1011.58 367347 928.19 2803 3559 4.53 3949 31.14 53.80 13.90 100.07 0.00 12.72 12.41
12/13 08:00 0.00 1011.57 367195 928.19 2463 3557 4.53 3949 30.76 53.90 12.40 100.06 7.20 12.86 12.31
12/13 09:00 0.00 1011.58 367347 928.19 1403 3557 4.53 3949 31.80 43.00 14.20 99.13 90.90 13.58 12.50
12/13 10:00 0.00 1011.55 366893 928.19 1721 3556 4.53 3949 32.52 36.00 17.00 97.87 223.80 14.73 13.22
12/13 11:00 0.00 1011.54 366742 928.19 2034 3553 4.53 3949 33.73 42.00 13.90 93.38 362.70 14.74 13.59
12/13 12:00 0.00 1011.53 366591 928.19 2300 3552 4.53 3949 36.32 34.40 12.00 86.13 436.70 14.28 13.41
12/13 13:00 0.00 1011.53 366591 928.18 3292 3552 4.52 3927 38.97 30.50 13.20 78.33 451.50 14.25 13.26
12/13 14:00 0.00 1011.55 366893 928.17 3441 3553 4.51 3906 41.70 29.90 15.70 71.33 433.60 14.21 13.19
12/13 15:00 0.00 1011.56 367044 928.16 3273 3555 4.50 3884 43.12 22.10 20.30 68.32 341.00 14.22 13.12
12/13 16:00 0.00 1011.56 367044 928.16 2619 3555 4.50 3884 38.44 22.20 25.30 77.79 152.40 13.80 13.10
12/13 17:00 0.00 1011.53 366591 928.18 2965 3553 4.52 3927 35.65 17.80 24.40 84.13 39.60 13.04 13.06
12/13 18:00 0.00 1011.51 366288 928.17 1973 3550 4.51 3906 34.97 18.30 22.90 85.00 0.00 13.00 12.77
12/13 19:00 0.00 1011.54 366742 928.17 1823 3551 4.51 3906 33.30 20.70 23.50 82.06 0.00 12.97 12.67
12/13 20:00 0.00 1011.51 366288 928.18 1993 3551 4.52 3927 30.54 18.30 23.90 82.01 0.00 12.94 12.63
12/13 21:00 0.00 1011.49 365986 928.18 1993 3548 4.52 3927 28.27 18.70 23.20 85.55 0.00 12.91 12.60
12/13 22:00 0.00 1011.48 365835 928.18 956 3546 4.52 3927 26.13 17.50 22.60 90.04 0.00 12.88 12.57
12/13 23:00 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
Data processed at Sun 14Dec2025 05:02 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting January 1st, 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. You will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
KAWL.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
KAWL.Elev.Inst.1Hour.0.Ccp-Rev
KAWL.Stor.Inst.1Hour.0.Ccp-Rev
KAWL.Elev-Tailwater.Inst.1Hour.0.Ccp-Rev
KAWL.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
KAWL.Flow-Res Out.Ave.1Hour.1Hour.Rev-Regi-Flowgroup
KAWL.Stage.Inst.1Hour.0.Ccp-Rev
KAWL.Flow.Inst.1Hour.0.Ccp-Rev
KAWL.Temp-Air.Inst.1Hour.0.Ccp-Rev
KAWL.Dir-Wind.Inst.1Hour.0.Ccp-Rev
KAWL.Speed-Wind.Inst.1Hour.0.Ccp-Rev
KAWL.%-Humidity.Inst.1Hour.0.Ccp-Rev
KAWL.Irrad.Inst.1Hour.0.Ccp-Rev
KAWL.Volt-Battery.Inst.1Hour.0.Ccp-Rev
KAWL.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.