HRHO2: North Canadian River

                                SHEF ID:       HRHO2     North Canadian River near Harrah
STATION TYPE:
Regulating: Stage = 15.00, Flow = 8563

STAGE RIV-FLOW WTR-TEMP DIS-OXY PH CONDUCT BAT-LOAD
ft cfs F mg/l su umho/cm volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
02/24 00:00 3.50 170 50.58 10.00 8.35 1097 12.05
02/24 01:00 3.51 172 50.00 9.86 8.33 1102 12.04
02/24 02:00 3.51 172 49.44 9.75 8.33 1116 12.03
02/24 03:00 3.52 174 48.78 9.74 8.33 1120 12.01
02/24 04:00 3.52 174 48.07 9.79 8.31 1131 11.99
02/24 05:00 3.53 176 47.46 9.84 8.28 1129 11.96
02/24 06:00 3.53 176 46.85 9.85 8.24 1134 11.94
02/24 07:00 3.53 176 46.45 9.96 8.21 1133 11.92
02/24 08:00 3.53 176 46.35 10.53 8.24 1138 11.91
02/24 09:00 3.52 174 46.83 11.10 8.28 1137 12.11
02/24 10:00 3.52 174 48.09 11.54 8.33 1144 12.63
02/24 11:00 3.52 174 49.95 11.83 8.37 1141 12.86
02/24 12:00 3.52 174 51.96 12.07 8.41 1151 12.90
02/24 13:00 3.51 172 53.85 12.20 8.44 1147 12.98
02/24 14:00 3.51 172 55.47 12.30 8.49 1155 12.97
02/24 15:00 3.50 170 56.48 12.35 8.52 1143 13.01
02/24 16:00 3.50 170 56.82 12.31 8.58 1148 12.93
02/24 17:00 3.49 168 56.64 12.15 8.61 1133 13.07
02/24 18:00 3.49 168 56.16 11.58 8.60 1146 12.90
02/24 19:00 3.49 168 55.65 10.99 8.56 1135 12.54
02/24 20:00 3.49 168 55.18 10.45 8.52 1143 12.31
02/24 21:00 3.49 168 54.81 10.02 8.48 1136 12.14
02/24 22:00 3.49 168 54.46 9.65 8.45 1152 11.99
02/24 23:00 3.49 168 54.30 9.52 8.42 1147 11.90
Data processed at Wed 25Feb2026 05:25 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting early 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. When this migration completes you will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
HARR.Stage.Inst.1Hour.0.Ccp-Rev
HARR.Flow.Inst.1Hour.0.Ccp-Rev
HARR.Temp-Water.Inst.1Hour.0.Ccp-Rev
HARR.Conc-DO.Inst.1Hour.0.Ccp-Rev
HARR.pH.Inst.1Hour.0.Ccp-Rev
HARR.Cond-Water.Inst.1Hour.0.Ccp-Rev
HARR.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.