HEYO2: Heyburn Lake

                                SHEF ID:       HEYO2     Heyburn Lake
STATION TYPE: RESERVOIR
Flood Pool: Bottom = 761.50, Top = 784.00

PRECIP ELEVATION STORAGE INFLOW RELEASE AIR-TEMP WIND-DIRWIND-SPEED REL-HUMID SOLAR-RAD VOLTAGE BAT-LOAD
in ft ac-ft cfs cfs F deg mph % W/m2 volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Rev-Regi Rev-Regi Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
05/20 00:00 0.03 762.08 5923 41 66 77.83 144.70 1.00 74.39 0.00 12.92 12.53
05/20 01:00 0.00 762.08 5923 51 66 74.97 159.20 5.90 82.31 0.00 12.90 12.53
05/20 02:00 0.01 762.08 5923 82 66 78.24 24.60 5.30 67.51 0.00 12.89 12.52
05/20 03:00 0.00 762.08 5923 105 66 75.81 93.20 2.30 76.31 0.00 12.87 12.50
05/20 04:00 0.31 762.09 5931 148 67 67.82 346.20 15.70 85.18 0.00 12.85 12.47
05/20 05:00 0.21 762.10 5940 171 69 63.79 14.50 10.50 94.86 0.00 12.83 12.46
05/20 06:00 0.24 762.12 5957 193 72 64.24 86.60 7.20 92.89 0.00 12.81 12.46
05/20 07:00 0.00 762.13 5965 258 74 63.66 142.50 4.90 95.75 0.00 12.79 12.43
05/20 08:00 0.00 762.14 5974 365 76 63.91 118.30 2.20 94.06 6.90 13.05 12.70
05/20 09:00 0.00 762.18 6008 494 83 65.12 145.50 3.30 91.97 123.80 13.48 13.16
05/20 10:00 0.00 762.24 6059 647 94 68.11 138.70 3.90 86.66 296.10 13.50 13.15
05/20 11:00 0.00 762.32 6126 803 110 72.12 154.00 5.50 78.80 467.20 13.52 13.12
05/20 12:00 0.00 762.40 6194 920 127 76.05 153.50 6.50 74.32 610.30 13.54 13.09
05/20 13:00 0.00 762.48 6262 978 144 80.20 158.10 6.80 70.46 728.10 13.46 13.19
05/20 14:00 0.00 762.57 6338 975 164 84.13 174.40 8.30 60.96 806.70 13.64 13.05
05/20 15:00 0.00 762.65 6406 973 183 85.71 173.10 7.50 55.07 824.20 13.58 13.00
05/20 16:00 0.00 762.72 6466 929 200 86.72 164.40 7.30 52.43 644.70 14.03 13.09
05/20 17:00 0.00 762.79 6525 843 217 87.66 176.70 6.70 50.20 733.00 13.58 13.02
05/20 18:00 0.00 762.84 6567 754 230 87.48 166.90 6.40 50.00 573.60 13.54 12.93
05/20 19:00 0.00 762.88 6601 663 240 86.88 163.60 5.60 50.49 404.20 13.51 13.00
05/20 20:00 0.00 762.91 6627 550 248 85.91 160.20 5.20 52.85 259.70 13.14 12.73
05/20 21:00 0.00 762.93 6644 493 254 84.00 162.80 3.70 57.31 85.70 12.99 12.60
05/20 22:00 0.00 762.94 6652 416 256 80.85 163.70 3.20 65.72 0.30 12.96 12.57
05/20 23:00 0.00 762.95 6661 ---- ---- 78.84 167.70 3.30 66.79 0.00 12.94 12.57
Data processed at Tue 21May2024 04:02 GMT

Parsing this webpage?

Checkout our new Data API! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
HEYB.Precip-Inc.Total.1Hour.1Hour.Ccp-Rev
HEYB.Elev.Inst.1Hour.0.Ccp-Rev
HEYB.Stor.Inst.1Hour.0.Ccp-Rev
HEYB.Flow-Res In.Ave.1Hour.1Hour.Rev-Regi-Computed
HEYB.Flow-Res Out.Inst.1Hour.0.Rev-Regi-Flowgroup
HEYB.Temp-Air.Inst.1Hour.0.Ccp-Rev
HEYB.Dir-Wind.Inst.1Hour.0.Ccp-Rev
HEYB.Speed-Wind.Inst.1Hour.0.Ccp-Rev
HEYB.%-Humidity.Inst.1Hour.0.Ccp-Rev
HEYB.Irrad.Inst.1Hour.0.Ccp-Rev
HEYB.Volt-Battery.Inst.1Hour.0.Ccp-Rev
HEYB.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.