BBRO2: Mountain Fork, Broken Bow Rereg

                                SHEF ID:       BBRO2     Mountain Fork Re-regulation Dam
STATION TYPE:

STAGE RIV-FLOW VOLTAGE BAT-LOAD
ft cfs volt volt
Ccp-Rev Ccp-Rev Ccp-Rev Ccp-Rev
(America/Chicago)
10/13 00:00 392.08 1340 13.19 12.48
10/13 01:00 391.67 1168 13.18 12.50
10/13 02:00 391.30 1027 13.18 12.50
10/13 03:00 390.97 910 13.19 12.50
10/13 04:00 390.68 774 13.18 12.50
10/13 05:00 390.42 670 13.19 12.50
10/13 06:00 390.20 593 13.19 12.50
10/13 07:00 389.99 526 13.19 12.50
10/13 08:00 389.81 464 13.17 12.50
10/13 09:00 389.64 412 13.19 12.50
10/13 10:00 389.50 373 13.17 12.50
10/13 11:00 389.36 339 13.19 12.49
10/13 12:00 389.25 313 13.20 12.48
10/13 13:00 389.14 290 13.19 12.47
10/13 14:00 389.04 271 13.19 12.44
10/13 15:00 388.95 254 13.19 12.43
10/13 16:00 389.12 286 13.19 12.44
10/13 17:00 391.54 1116 13.19 12.44
10/13 18:00 393.89 2238 13.19 12.44
10/13 19:00 394.64 2643 13.19 12.45
10/13 20:00 394.02 2320 13.19 12.46
10/13 21:00 393.40 1946 13.19 12.47
10/13 22:00 392.85 1663 13.18 12.47
10/13 23:00 392.35 1445 13.13 12.47
Data processed at Tue 14Oct2025 04:34 GMT

NOTICE: If you are parsing this page

Please convert to using our Data API. Starting January 1st, 2026 we will be migrating to: https://water.usace.army.mil with modern pages rendered in JavaScript. You will no longer be able to scrape this page! CWMSDataAPI (CDA)

Timeseries IDs (TSIDs)

TSIDs used from left to right in the data table
BROM.Stage.Inst.1Hour.0.Ccp-Rev
BROM.Flow.Inst.1Hour.0.Ccp-Rev
BROM.Volt-Battery.Inst.1Hour.0.Ccp-Rev
BROM.Volt-Battery Load.Inst.1Hour.0.Ccp-Rev

                            

All information presented herein is the property of the government of the United States of America and may be revised or deleted at any time without prior notice. Dissemination of this information without the expressed written consent of the Public Affairs Office, Tulsa District U.S. Army Corps of Engineers is strictly prohibited. These data are gathered electronically and, as presented, have NOT undergone any form of quality control. These data are NOT guaranteed to be valid or correct.